Fixed Veterinary X-ray Systems & Pet DR
Mobile Pet X-ray Combined System
Tube head, high-voltage generator, collimator and radiographic table combined freely, with 20–50 kW output and up to 630 mA. The cassette trolley accepts CR, DR and IP plates in different sizes.

Pet X-ray Combined System
| Tube head power | 20kW (200mA@100kV) / 30kW (300mA) / 40kW (400mA) / 50kW (500mA), up to 630mA |
|---|---|
| Collimator | Max field 440×440mm (SID 100cm), light field >160lux, contrast >4:1, inherent filtration 1mmAl at 75kV |
| Radiographic table | Densified board top 140×72.5cm, table height 75cm with castors, column 200–212cm, 3 positions |
| Tabletop travel | Lateral 90cm / longitudinal 40cm, cassette travel 23cm |
| Focal distances | Focal spot to grid 113cm, focal spot to tabletop 110cm (lowest position) |
| Flat panel (optional) | CsI 17×17, 3072×3072, 139μm, 16bit, 3.6lp/mm, 1s imaging, wired or wireless |
| Exposure method | Hand switch / remote control |

Pet X-ray System with Self-produced Tube Head
A three-part package: mobile radiographic table, our own 5kW portable generator and an optional flat panel detector. Castors let one table serve several rooms.
| kV / mA | 40–120kV | 20–125mA |
|---|---|
| mAs / exposure time | 0.1–250mAs | 1–3200ms |
| Input power / output | 220–240VAC | 5kW |
| Generator unit | 46×27.5×20.5cm, 14.5kg |
| Radiographic table | Densified board top 1400×725mm, height 750mm with castors, column 2000–2120mm, 3 positions |
| Tabletop travel | Lateral 900mm / longitudinal 400mm, cassette travel 230mm |
| Detector (optional) | CsI 14×17, 2560×3072, 139μm, 16bit, 3.6lp/mm, 1s imaging, wired |
80kW 1000mA Large Animal DR
Locate foreign bodies in the digestive tract of cattle, horses and sheep with confidence. Supplied with a bovine / equine / ovine restraint chute and a two-column tube stand — the imaging choice for referral hospitals, large farms and pharmaceutical research units.

80kW 1000mA Large Animal DR System
| X-ray tube | Focal spot 0.6/1.2 | max 150kV | anode angle 12° | heat capacity 260/350kJ | cooling rate 1200W | rotation 10800 min⁻¹ | max power 34/80kW (0.1s) |
|---|---|
| High-voltage generator | 80kW output | 380VAC±10% three-phase | 40–150kV (1kV steps) | 10–1000mA | 1–10000ms | 1–630mAs | APR storage 2400 sets |
| Collimator | Max field 440×440mm (SID 1000mm), manual continuous adjustment, 8.0±0.5kg |
| Two-column stand | Column travel 0–153cm | tube vertical 40–120cm | arm rotation ±90° | cassette holder 0–138cm | holder for 17×17 inch |
| Flat panel detector | CsI | active 430×430mm | 3072×3072 | 139μm | 16bit | 3.5lp/mm | 1s acquisition | 40–160kV | Gigabit Ethernet | 3.8kg |
| HV cables | 90kV 8M × 2 |
| Workstation | Desktop or laptop, software pre-installed and calibrated before shipment |
| Restraint chute | Single-head chute for cattle / horse / sheep × 1 |
On site
Restraint chute
Tube stand
X-ray tubeStandard scope of supply: X-ray tube ×1, 80kW 380V generator ×1, collimator ×1, HV cables ×2, two-column stand ×1, flat panel detector with software ×1, desktop or laptop ×1, restraint chute ×1. Sold factory direct, cutting out distributors and lowering both purchase and service costs.
Need Room Layout Advice?
Fixed systems have power supply and radiation protection requirements. Send us your room dimensions and electrical supply and we will advise on layout free of charge.
Get a Room Plan & QuotationPhone / WhatsApp: +86 19062611512 | admin@newheek.cn